smart level control
Optional module for water testing on sewage manholes/pipes in accordance with EN 1610 in
conjunction with the EDS2 level probe and smart memo.
In the event of a drop in level during the test, the smart level control automatically tops up the
test area with water to maintain the initial level. The amount of water added is automatically
measured and the measured value is sent to the smart memo.
The smart level control is connected to the smart memo via an additional B11 termination
cable.
A container for use as a water reservoir should be positioned at least 0.5 metres above the
smart level control and connected to it via a hose.
Technical data:
Operating temperature: +5°C to 40°C
Max. flow rate: 20 l/h (with sufficient inlet pressure, e.g. 50 cm water gauge)
Accuracy: +-5% (at 0 - 0.3 l/min)
Max. inlet pressure: 0.1 bar (1 metre water column)
Mechanical connections: nipple (Series 21) on the inlet side, coupling (Series 21) on the outlet
side
Electrical connections: 1x socket B11 (power supply via smart memo)
Connecting hoses are included in the scope of delivery