Produkty
Technologia urządzenia OLLI Tracer Gas
OLLI Tracer Gas - 280050
OLLI Tracer Gas
Portable gas leak detector with integrated pump, bluetooth and Li-Ion battery for leak detection using forming gas (5% H2 in 95% N2).
Extremely resistant 2K plastic housing
Operating time > 35 hours (depending on ambient conditions, without lighting)
Pump flow approx. 20 l/h
Dimensions (LxWxH): 170 x 80 x 43 mm,
Weight: approx. 380 g
Description of the OLLI Tracer Gas detector
Water is a scarce and therefore precious resource that must be protected by all available means. This means that leaks in drinking water distribution systems must be detected quickly in order to minimise water losses.
Gas leak detection using forming gas (or tracer gas) is used to locate the smallest leaks in drinking water pipes, household installations or heating and cooling systems that cannot be detected using acoustic methods. This method is also used to detect leaks in air conditioning systems in vehicles. In all cases, it is a relatively inexpensive way of locating leaks.
Here, "forming gas" is fed into a water pipe that is in operation. Forming gas usually consists of 5 vol.% hydrogen and 95 vol.% nitrogen. It is odourless and tasteless, non-flammable, non-explosive and non-toxic, i.e. harmless to humans and nature. Due to its low density, hydrogen is lighter than air and therefore rises upwards. This means that the gas can be easily detected with a suitable probe and the OLLI Tracer Gas. The gas is sucked in by the integrated pump and channelled to the sensor.
Features of the OLLI Tracer Gas detector
- Ergonomic and extremely durable plastic housing
- High-contrast LCD graphic display with backlighting for perfect visualisation of all measured values
- Display of all measured values
- Simple and easy handling thanks to intuitive menu navigation
- Brand new and highly effective filter technology
- Use of different probes possible thanks to internal pump
- Bluetooth technology for quick and easy data transfer
Technical data
Display | LCD graphic display with 128 x 64 pixels, illuminated + special symbols |
---|---|
Power supply | rechargeable Li-Ion |
Operating time | up to 35 hours (without lighting) |
Display range | 0 to max. 5 Vol.% H2 |
Alarm | audible, visual and vibrating alarm signals |
Operating temperature | -20 °C to +50 °C |
Protection class | IP67 |
Dimensions | approx. 80 x 170 x 43 mm |
Weight | approx. 380 g incl. battery |
Pump flow | approx. 20 l/h |
Data transmission | Bluetooth, IR |